Click to zoom
This gas detector works on the FID principle and is built for monitoring VOCs fugitive emissions. It quickly and accurately pinpoints leaks at pipe valves, discharge ports and enclosed facility systems, so teams can carry out repairs in good time and keep equipment and production running without interruption. It also supports environmental agencies in strengthening the monitoring and management of VOCs fugitive emissions from enterprises. The instrument holds an explosion-proof certificate issued by the authority department, which makes it safe to use and operate in environments that call for explosion-proof equipment.
The LY-3033 Portable THC Analyzer FID is a professional, field-ready gas detection instrument based on the Flame Ionization Detector (FID) principle, optimized for high-precision VOCs fugitive emission monitoring and leak localization. Designed for industrial users and environmental regulatory agencies, this FID VOCs detector quickly and accurately identifies VOC leaks across pipeline valves, discharge ports and enclosed facility systems. This supports proactive maintenance, uninterrupted industrial operation and strict environmental compliance management. An optional PID detection configuration lets it adapt flexibly to different on-site monitoring needs.
Explosion-Proof Safety for Hazardous Industrial Environments :
This explosion-proof VOCs analyzer carries authoritative explosion-proof certification, allowing safe and compliant operation in high-risk explosive atmospheres. This is essential for petrochemical and refining facilities.
High-Precision Dual-Detection System :
It is equipped with a high-sensitivity, multi-range FID detector and an optional PID module. The detection limit is as low as 0.5 ppm, and the response time is under 3.5 s to reach 90% of the final reading, so leaks are captured accurately in real time.
Portable & Intuitive Operation :
The fully molded, lightweight body (under 3.1 kg) can be carried over the shoulder or diagonally with the included strap. The explosion-proof display controller offers wireless control for simple one-handed operation in complex field environments.
Intelligent System & Self-Diagnosis :
A built-in full self-test function automatically checks the instrument status and gives fault prompts to simplify maintenance. The analyzer also integrates with the optional LDAR (leak detection and repair) data platform, enabling full-process, systematic management of detection workflows.
The LY-3033 Portable THC Analyzer FID complies with the latest environmental monitoring standards and regulations issued by the Ministry of Ecology and Environment of China, as well as relevant international standards. It has obtained the China Environmental Protection Product Certification (CPA) and authoritative explosion-proof certification, which supports data validity and legal compliance for enterprise environmental reporting and regulatory enforcement.
| Main Parameter | Parameter Range |
|---|---|
| Measuring Range | FID: (1.0 ~ 50,000) ppm methane PID: (0.5 ~ 2,000) ppm isobutylene |
| Response Time | FID: ≤ 3.5 s to reach 90% of final value using 10,000 ppm methane PID: ≤ 3.5 s to reach 90% of final value using 500 ppm isobutylene |
| Repeatability | FID: ±2% at 500 ppm methane PID: ±2% at 100 ppm isobutylene |
| Accuracy | FID: ±10% of reading or ±0.1 ppm, whichever is greater, from 1.0 to 10,000 ppm PID: ±20% of reading or ±0.5 ppm, whichever is greater, from 0.5 to 2,000 ppm |
| Linearity Range | Full scale |
| Warm-up Time | < 20 min |
| Lower Detection Limit | FID: 0.5 ppm methane PID: 0.5 ppm isobutylene |
| Operating Conditions | Ambient temperature: (-10 ~ 50) °C; Relative humidity: ≤ 90%; Atmospheric pressure: (86 ~ 106) kPa |
| Sampling Flow Rate | Approx. 0.8 L/min |
| Gas Duration | ≥ 10 h |
| Battery Life | ≥ 10 h |
| Communication | Bluetooth or Wi-Fi |
| Power Consumption | < 4 W |
| Dimensions (L×W×H) | 258 mm × 191 mm × 82 mm |
| Weight | < 3.1 kg |
Petrochemical & Refining Industrial Facilities :
Routine inspection of pipelines, valves and storage tanks to detect industrial leaks, trace VOC leak sources, prevent safety accidents and protect workplace safety.
Environmental Remediation & Site Investigation :
Rapid screening of VOC-contaminated areas at soil and groundwater remediation sites, real-time tracking of remediation progress and accurate definition of pollution boundaries.
Environmental Emergency Response :
Quick identification of VOC concentration and dispersion range at leak, fire or other environmental accident scenes, giving emergency teams real-time data to support decisions and personnel evacuation.
Occupational Health & Compliance Management :
Monitoring VOC exposure levels in workers' breathing zones, assessing occupational health risks and supporting compliance with indoor and workplace air quality standards.
The LY-3033 is produced by an established provider of professional environmental monitoring solutions for industrial clients. It is certified, field-proven equipment with long maintenance cycles and intuitive operation. Support includes pre-sales consultation, customized on-site training, complete operation and maintenance manuals, and full after-sales technical support, helping enterprise users achieve efficient, compliant environmental monitoring and management.
Here are some frequently asked questions about the LY-3033. If you have any question which is not answered here, please feel free to contact us.
It uses the industry-standard Flame Ionization Detector (FID) principle for total hydrocarbon and VOC detection, with an optional Photoionization Detector (PID) module to extend detection capability for different industrial scenarios.
Yes. It has obtained authoritative explosion-proof certification, ensuring safe and stable operation in environments with explosion-proof requirements.
The analyzer supports Bluetooth and Wi-Fi communication and can connect to the optional LDAR (leak detection and repair) data platform, providing a fully systematic detection process and traceable data.
Please Subscribe our news letter and and get update.